THIS CHART IS ONLY A GUIDE AND SHOULD NOT BE USED TO OPERATE THE CRANE.
The individual crane’s load chart, operating instructions and other instructional plates must be read and understood prior to operating the crane
25Grove RT9130E
Load handling
When lifting over swingaway and/or jib combinations,
deduct total weight of all load handling devices reeved
over main boom nose directly from swingaway or jib
capacity.
NOTE: All load handling devices and boom attachments
are considered part of the load and suitable allowances
MUST BE MADE for their combined weights. Weights are
for Grove furnished equipment.
Hoist performance
Wire
rope
layer
Hoist line pulls
twospeed hoist
Drum rope
capacity ft
Low
available
lb*
High
available
lb*
Layer Total
1 20,024 12,496 140 140
2 18,405 11,485 152 293
3 17,028 10,626 165 458
4 15,842 9886 177 636
5 14,811 9243 190 826
6 13,906 8678 202 1028
* Max lifting capacity:
6 x 37 class or 35 x 7 class = 16,800 lb
Working area diagram
Bold lines determine the limiting position of any load for operation within working areas indicated.
Line pulls and reeving information
Hoists Cable specs
Permissable
line pulls
Nominal cable
length
Main
Model 35
19 mm (3/4 in)
6 x 37 class, EIPS, IWRC
Special Flexible Min.
Breaking Str. 58,800 lb
16,800 lb 950 ft
Main
Model 35
19 mm (3/4 in) Flex-X 35
Rotation resistant (non-
rotating) Min. breaking Str.
85,500 lb
16,800 lb 950 ft
Auxiliary
Model 35
19 mm (3/4 in) Flex-X 35
Rotation resistant (non-
rotating) Min. breaking Str.
85,500 lb
16,800 lb 700 ft
The approximate weight of 3/4 in wire rope is 1.5 lb/ft
Weight reductions for load handling devices
Reeving diagram
ft ft luffing folding boom
extension
Pounds
*36 ft extension (erected) 5260
*59 ft extension (erected)
9860
Luffing extension with ft
insert
Pounds
*59 ft extension (erected) 14,100
Luffing extension with ft
insert
Pounds
*59 ft extension (erected) 19,400
Auxiliary boom nose Pounds
120
Hookblocks and headache balls Pounds
80 USt, 5-sheave 1600+
130 USt, 8-sheave 2400+
10 USt overhaul ball 690+
+Refer to rating plate for actual weight.
When lifting over boom nose with 36 ft or 59 ft extension
erected, the outriggers must be fully extended or 50%
extended (19 ft 9 in) spread.
When lifing over main boom nose with 36 ft or 52 ft insert
erected, the outriggers must be fully extended.
CENTERLINE
OF BOOM
DIAGRAM
FOR LIFTING
ON OUTRIGGERS
CENTERLINE
OF OUTRIGGER
SUPPORT
LONGITUDINAL
CENTERLINE
OF CRANE
SEE NOTE
AT BOTTOM
CENTERLINE