Part Number STH025 11/16 179
ICE THICKNESS PROBE INITIATES HARVEST
FUNCTION
The ice thickness probe senses ice on the evaporator and
signals the control board to start a harvest cycle.
SPECIFICATIONS
Freeze Time Lock-In Feature
The ice machine control system incorporates a 6 minute
freeze time lock-in feature. This prevents the ice machine
from short cycling in and out of harvest.
Maximum Freeze Time
The maximum freeze time is 35 minutes at which time the
control board automatically initiates a harvest sequence.
Firmware 5.009 or earlier - Maximum freeze time is 60
minutes at which time the control board automatically
initiates a harvest sequence.
Maximum Temperature
Maximum temperature for the ice thickness probe is
120°F (49°C). Do not clean probe in a dishwasher or
expose to temperatures above the maximum.