Manitowoc F2314-17
07-20-21
MLC80A-1/MLC90A-1/MLC100A-1/MLC100-1 LUBRICATION GUIDE
Item Description Required Service
Quarterly or Every 250 Hours of Engine Operation (whichever comes first)
Q1 Hook-and-Weight Ball Swivel (1 fitting) Grease.
Q2 Load Block (3 fittings) Grease.
Q3 Tagline Gears (1 fitting) Grease (grease will drop onto gears).
Q4 Tagline Level Plug (1 each barrel) Check level of each barrel with tagline horizontal. Oil
should be up to plug opening.
Q5 Tagline Fill Plug (1 each barrel) Fill each barrel to proper level with SAE 90 heavy-duty
gear oil. See decal on tagline.
Yearly or Every 2000 Hours of Crane Operation (whichever comes first)
Y1 Boom Sheaves The boom and jib sheaves are packed with grease at
assembly and do not require greasing at regular
intervals.
Inspect the boom and jib sheaves for proper operation
yearly or every 2000 hours of crane operation. Overhaul
the sheaves and repack them with grease if needed.
Y2 Jib Sheaves
Yearly or Every 2000 Hours of Crane Operation (whichever comes first)
or at a Desired Interval if the Sheaves are Equipped with Sealed Bearings and Grease Fittings
YD1 Boom Sheaves The boom and jib sheaves are packed with grease at
assembly and do not require greasing at regular
intervals. If the sheaves are equipped with sealed
bearings and grease fittings, they can be greased at a
desired interval established by the crane owner/user.
Inspect the boom and jib sheaves for proper operation
yearly or every 2000 hours of crane operation. Overhaul
the sheaves and repack them with grease if needed.
YD2 Jib Sheaves