4-4
Maintenance Section 4
E. Remove the Float Valve
Turn the splash shield counterclockwise one or
two turns.
Float Valve Removal
Pull the float valve forward and off the mounting
bracket.
Disconnect the water inlet tube from the float
valve at the compression fitting.
Remove the cap and filter screen for cleaning.
F. Remove the Water Trough
Apply downward pressure on the siphon tube and
remove from the bottom of the water trough.
Remove the upper thumbscrew.
While supporting the water trough remove the
two thumbscrews from beneath the water trough.
Remove the water trough from the bin area