EasyManuals Logo
Home>Manitowoc>Ice Maker>Q130

Manitowoc Q130 User Manual

Manitowoc Q130
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
Operation Section 3
3-4
Part Number 000001130 12/08
Operational Checks
GENERAL
Your Manitowoc ice machine was factory-operated and
adjusted before shipment. Normally, a newly installed ice
machine does not require any adjustment.
To ensure proper operation, always follow these
Operational Checks when starting the ice machine:
for the first time
after a prolonged out of service period
after cleaning and sanitizing
Routine adjustments and maintenance procedures
outlined in this manual are not covered by the warranty.
SIPHON SYSTEM
To reduce mineral build-up and cleaning frequency, the
water in the sump trough must be purged during each
harvest cycle.
When the water pump de-energizes the level in the
water trough rises above the standpipe starting a siphon
action. The siphon action stops when the water level in
the sump trough drops. When the siphon action stops,
the float valve refills the water trough to the correct level.
Siphon System Check
Follow steps 1 through 6 under water level check.
WATER FLOAT VALVE CHECK
Before water will flow into the water trough the float
valve shut-off must be in the OPEN position.
Water Level
WATER
LEVEL
SIPHON
CAP
STANDPIPE
DRAIN
PRESS TO
OPEN
PRESS TO
CLOSE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Q130 and is the answer not in the manual?

Manitowoc Q130 Specifications

General IconGeneral
BrandManitowoc
ModelQ130
CategoryIce Maker
LanguageEnglish

Related product manuals