4-1
Section 4 Maintenance
Disassembling the Dispenser Parts
For Cleaning
WARNING
Unplug unit before servicing or cleaning.
Electric Shock Hazard.
1 Shut off water to ice machine.
2 Locate a cylindrical object, such as a ballpoint
pen with a cap on the pen.
Insert the pen into the left and right black rubber
holes in the top of the front panel of the
dispenser.
This action releases the two clips which hold the
dispenser front panel in place.
While applying pressure on the pen, pull the front
panel forward slightly, so the clip in the panel
does not snap back into place.
3 Hold the front panel of the dispenser on both
sides and tilt the panel forward. The front panel
will be resting on the catch hooks at the bottom of
the panel.
4 Disconnect water line at the front panel “quick
disconnect” fitting. This water line feature is
only on model QFA-291
Black rubber
holes
Dispenser
Front
Panel
Catch
Hook