Part Number: 000015431 Rev01 5/19 185
IT1200C/CVDT1200
Remote Air-Cooled Condensing Unit Model
Characteristics vary depending on operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10 70/21 90/32
-20 to 70/
-29 to 21
6.4-7.7 7.4-8.8 7.8-9.4
.75-2.5
80/27 7.2-8.6 7.7-9.1 8.2-9.7
90/32 7.6-9.0 8.0-9.5 8.8-10.4
100/38 8.3-9.9 8.5-10.1 9.9-11.8
110/43 8.9-10.6 9.7-11.5 10.5-12.4
1
Times in minutes - Dice cube
24-Hour Ice Production
Air Temp. Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10 70/21 90/32
-20 to 70/
-29 to 21
1075 1005 955
80/27 1025 975 925
90/32 985 940 870
100/38 910 890 780
110/43 860 800 745
1
Based on average ice slab weight of 6.2 - 7.2 lb.
Operating Pressures
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
-20 to 50/
-29 to 10
230-340 70-40 155-200 110-135
70/21 275-350 70-40 160-210 110-130
80/27 290-360 70-41 170-210 115-140
90/32 310-370 75-41 180-210 120-140
100/38 365-470 90-44 220-315 130-175
110/43 375-480 90-45 225-320 150-175