Step 8 Use 1/2 of the cleaner/water mixture to clean
all components. The cleaner solution will foam when it
contacts lime scale and mineral deposits; once the foaming
stops use a soft-bristle nylon brush, sponge or cloth (NOT
a wire brush) to carefully clean the parts. Soak parts for 5
minutes (15 - 20 minutes for heavily scaled parts). Rinse all
components with clean water.
Step 9 While components are soaking, use 1/2 of the
cleaner/water solution to clean all food zone surfaces of
the ice machine and bin (or dispenser). Use a nylon brush
or cloth to thoroughly clean the following ice machine
areas:
Side walls
Base (area above water trough)
Evaporator plastic parts - including top, bottom, and
sides
Bin or dispenser
Rinse all areas thoroughly with clean water.
SANITIZING PROCEDURE
Step 10 Mix a solution of sanitizer and lukewarm water.
Solution
Type
Water Mixed With
Sanitizer 3 gal. (12 L) 2 oz (60 ml) sanitizer
Step 11 Use 1/2 of the sanitizer/water solution to
sanitize all removed components. Use a spray bottle to
liberally apply the solution to all surfaces of the removed
parts or soak the removed parts in the sanitizer/water
solution. Do not rinse parts after sanitizing.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QuietQube Series and is the answer not in the manual?

Manitowoc QuietQube Series Specifications

General IconGeneral
BrandManitowoc
ModelQuietQube Series
CategoryIce Maker
LanguageEnglish

Related product manuals