Water System Ice Making Sequence of Operation Section 5
5-2 Part No. 80-1100-3
HARVEST CYCLE
4. The water pump and water dump solenoid are
energized for 45 seconds to purge the water from
the water trough. The water fill valve energizes for
the last 15 seconds of the 45-second purge cycle, to
flush sediment from the bottom of the water trough.
5. After the 45-second purge, the water pump and
water dump valve de-energize.
AUTOMATIC SHUT-OFF
There is no water flow during an automatic shut-off.
Figure 5-2. Water Flow Down the Drain
SV1677
TO DRAIN
WATER DUMP VALVE
TO DISTRIBUTION TUBE
WATER PUMP
WATER INLET VALVE

Table of Contents