–37–
CLEANING PROCEDURE
Ice machine cleaner is used to remove lime scale or
other mineral deposits. It is not used to remove algae
or slime. Refer to “Sanitizing Procedure” on page 39
for removal of algae and slime. To initiate a cleaning
cycle using Manitowoc’s Patented Cleaning
Technology, use the following procedure.
Step 1. Set the toggle switch to the OFF position after
ice falls from the evaporator at the end of a Harvest
cycle. Or, set the switch to the OFF position and allow
the ice to melt off the evaporator.
Step 2. To start a cleaning cycle, move the toggle
switch to the CLEAN position. The water will flow
through the water dump valve and down the drain. The
Clean light* will turn on to indicate the ice machine is
in the cleaning mode.
Step 3. Wait about one minute or until water starts to
flow over the evaporator.
Step 4. Add the proper amount of Manitowoc Ice
Machine Cleaner to the water trough.
*The Q1400C ice machine control board does not energize a
Clean light.
!
Caution
Never use anything to force ice from the evaporator.
Damage may result.
QuietQube
®
Models Amount of Cleaner
Q0600C/Q0800C/
SU1000C/Q1400C
5 ounces (150 ml)
Q1000C/QDUAL 9 ounces (270 ml)