Step 6 Fill the evaporator and reservoir with cleaning
solution.
Step 7 Move the toggle switch to the ON position.
The ice machine will make ice with the cleaning
solution and deposit the ice in the bin. Add the
remaining cleaner/water solution as the water level in
the reservoir drops.
NOTE: Do not allow the cleaner/water level to drop
below the minimum water level. The ice machine will
discontinue the cleaning cycle if the water float switch
opens.
Step 8 After all of the cleaner/water solution has
been added turn on the ice making water supply.
Continue the freeze cycle for 10 minutes to remove
the cleaning solution from the water circuit.
Prop Float Up to Prevent Low
Water Level Shutdown