52 Part Number 000007661 6/13
PARTS REMOVAL FOR CLEANING/SANITIZING
1. Turn off the water supply to the ice machine at the
water service valve.
2. Remove the components listed on the following
pages for cleaning and sanitizing.
3. Soak the removed part(s) in a properly mixed
solution of cleaner and water.
!
Warning
Disconnect electric power to the ice machine at
the electric switch box and wear rubber gloves
and safety goggles (or face shield) while handling
cleaner or sanitizer.
!
Caution
Do not mix Cleaner and Sanitizer solutions
together. It is a violation of Federal law to use
these solutions in a manner inconsistent with
their labeling.
Solution Type Water Mixed With
Cleaner 1 gal. (4 L) 16 oz (500 ml) cleaner
Part Number 000000084