Maintenance Section 4
23
Part Number 000007644 3/11
Removal of Parts for Cleaning/Sanitizing
1. Turn off the water supply to the ice machine at the
water service valve.
2. Remove the components listed on the following
pages for cleaning and sanitizing.
3. Soak the removed part(s) in a properly mixed
solution of cleaner and water.
4. Use a soft-bristle brush or sponge (NOT a wire
brush) to carefully clean the parts.
5. Use the solution and a brush or sponge to clean all
disassembled components and the inside of the bin.
6. Rinse all cleaned parts with clear water.
7. Mix a solution of sanitizer and water.
8. Soak the parts in the sanitizer/water solution for
10 minutes. Use the sanitizer/water solution and a
sponge to sanitize all removed components and the
inside of the bin. Do not rinse the sanitized parts.
9. Continue with step 11 of the cleaning/sanitizing
procedure.
ICE CHUTE REMOVAL
RFS0300/RFS0650/RF1200/RF2300 Only
1. Place the toggle switch in the OFF position, turn off
the water supply and disconnect electrical power to
the ice machine.
2. Disconnect water supply.
3. Remove water reservoir cover.
4. Remove microswitch and bin thermostat from the ice
chute.
5. Remove retainer, ice chute elbow and ice chute.
Disconnect electric power to the ice machine at the
electric switch box and wear rubber gloves and
safety goggles (or face shield) while handling
cleaner or sanitizer.
Do not mix Cleaner and Sanitizer solutions together.
It is a violation of Federal law to use these solutions
in a manner inconsistent with their labeling.
Solution Type Water Mixed With
Cleaner 1 gal. (4 L)
16 oz (500 ml) cleaner
Part Number 000000084
Solution Type Water Mixed With
Sanitizer 3 gal. (11 L)
2 oz (60 ml) sanitizer
Part Number 94-0565-3