36 Part Number 000007661 6/13
RN1000/RN1400
Self-Contained Air-Cooled & Water-Cooled
NOTE: Ice machines use an auger to remove ice from
the evaporator. Occasional noises (creaks, groans,
squeaks, or pops) are a normal part of the ice making
process.
Operation
The ice machine will not start until:
A. The rocker switch is moved to ON.
B. The transport tube shuttle switch is closed.
C. The water reservoir is full of water.
Placing the toggle switch in the ON position starts the
gear motor and refrigeration system. The water level
sensor controls the water inlet valve and water level.
The freeze cycle ends when ice contact opens the
transport tube switch. A 60 minute time delay period
initiates. The ice machine will restart when the ice
transport tube switch closes and the 60 minute time
delay period expires.
Flush Cycle
The ice machine will automatically flush the
evaporator.
The refrigeration system will shut down and the gear
motor will continue to run. After the flush is complete,
the machine will refill and start the refrigeration system
without a time delay.
Continued on next page …

Table of Contents

Other manuals for Manitowoc RF0650A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc RF0650A and is the answer not in the manual?

Manitowoc RF0650A Specifications

General IconGeneral
BrandManitowoc
ModelRF0650A
CategoryIce Maker
LanguageEnglish

Related product manuals