58 Part Number 000007661 6/13
RN MODELS CLEANING/SANITIZING PROCEDURE
Use Ice Machine Cleaner part number 000000084.
Use Ice Machine Sanitizer part number 94-0565-3.
Step 1 Remove all ice from the bin/dispenser.
Step 2 Remove front and top covers.
Step 3 Mix a solution of cleaner and water.
Step 4 To start a cleaning cycle, depress the CLEAN
switch to drain the water from the evaporator. Wait for
the LOW WATER light to energize.
Step 5 Remove cover from the cleaning cup and add
cleaner/water solution until the HI WATER light
energizes, then replace cleaning cup cover. The
machine will clean and then flush three times in
approximately twelve minutes.
Step 6 While the ice machine is in the clean cycle,
prepare for the sanitizing cycle by mixing a solution of
sanitizer and water.
Step 7 To start a sanitize cycle, depress the clean
switch to drain the water from the evaporator. Wait for
the LOW WATER light to energize.
Step 8 Remove cover from the cleaning cup and add
sanitizer/water solution until the HI WATER light
energizes, then replace cleaning cup cover. The
machine will sanitize and then flush three times in
approximately twelve minutes.
Amount of
Luke Warm Water
Amount of Cleaner
Part Number 000000084
1 gallon (4 Liters) 4 ounces (120 ml)
Amount of
Luke Warm Water
Amount of Sanitizer
Part Number 94-0565-3
1 gallon (4 L) Water 1/2 ounce (15 ml)

Table of Contents

Other manuals for Manitowoc RF1200A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc RF1200A and is the answer not in the manual?

Manitowoc RF1200A Specifications

General IconGeneral
BrandManitowoc
ModelRF1200A
CategoryIce Maker
LanguageEnglish

Related product manuals