Part Number 000007661 6/13 137
HI AMPS - GEAR MOTOR AMPERAGE EXCEEDS
3.8 AMPS
Soft Error
The control board stops the ice machine, energizes
the Hi Amps & Service lights and initiates a time delay
period. The ice machine will restart after the 60 minute
delay. The ice machine continues to run if amperage
remains below 3.8 amps for six hours.
Hard Error
Gear motor amperage exceeds 3.8 amps a second
time, within six hours of the first failure. The ice
machine must be reset by pressing the control board
reset button.
HI PRESSURE
Soft Error
If the refrigeration pressure exceeds 425 psi (2930
kPa) the ice machine will turn off, energize the Hi
Press light and initiate a 60 minute delay period. If the
refrigeration pressure is below 295 psi (2034 kPa) at
the end of the delay period the ice machine will restart.
DRAIN CLOG
Soft error
When the drain sensor (located in the drain pan
behind the drain solenoid) detects water, the ice
machine will energize the Drain Clog light and turn off
until reset.

Table of Contents

Other manuals for Manitowoc RF2300A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc RF2300A and is the answer not in the manual?

Manitowoc RF2300A Specifications

General IconGeneral
BrandManitowoc
ModelRF2300A
CategoryIce Maker
LanguageEnglish

Related product manuals