Part Number 000007661 6/13 51
Step 5 Refer to chart below:
Premix cleaner with lukewarm water in a
non-metallic container.
Step 6 Remove all water from the evaporator and
water reservoir. Add the entire cleaner/water solution
and re-install the reservoir cover.
Leave the cleaner/water solution in the evaporator
for a minimum of 4 hours.
Step 7 Remove all cleaner/water from the evaporator
and water reservoir.
Step 8 Follow the standard cleaning and sanitizing
procedures.
Model
Water
Reservoir
Capacity
Mix Cleaner and Water
Use Ice machine nickel safe
cleaner, part number
000000084 only
Cleaner Water
RF0244
RNS0244
RF0266
RNS0308
RF0385
RNS0385
RF0388
RF0399
RF0644
14 oz (400 ml) 9 oz (266 ml) 5 oz (148 ml)
RF0300
RNS0308
RF0650
17 oz (500 ml) 11 oz (325 ml) 6 oz (177 ml)
RF1200
RFS1200
34 oz (1 L) 23 oz (680 ml) 11 oz (325 ml)
RF2300