EasyManuals Logo
Home>Manitowoc>Ice Maker>RFS1279R

Manitowoc RFS1279R User Manual

Manitowoc RFS1279R
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #161 background imageLoading...
Page #161 background image
Part Number 000007661 6/13 161
Refrigeration Troubleshooting
CAPILLARY TUBE MODELS
If the gear motor and/or compressor are not energized refer to Electrical Troubleshooting
Refer to Operational Pressure Charts for normal pressures and temperatures
Low on
Refrigerant
Overcharge of
Refrigerant
Non Condensible
in System
Restricted Capillary
Tube
Discharge Pressure Low High High Low
Suction Pressure Low High High Low
Evaporator Inlet Temperature Normal Low High Low
Evaporator Outlet Temperature High Normal High Low
Compressor Discharge Line Temperature
Normal Range =
> 165° @ 70° - 210° @ 110°
> 74°C @ 21°C - 99°C @ 43°C)
High
Increases with
run time
Normal
High
Increases with
run time
High
Increases with
run time

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc RFS1279R and is the answer not in the manual?

Manitowoc RFS1279R Specifications

General IconGeneral
BrandManitowoc
ModelRFS1279R
CategoryIce Maker
LanguageEnglish

Related product manuals