Section 6 Electrical System
Part Number 80-1480-3 6-11
REMOTE MODELS
Initial Start-Up Or Start-Up After
Automatic Shut-Off
1. WATER PURGE
Before the compressor starts, the
water pump and water dump
solenoid are energized for 45
seconds to purge old water from the
ice machine. This ensures that the
ice-making cycle starts with fresh
water.
NOTE: The harvest valve and
harvest pressure regulating (HPR)
solenoid valve are also energized
during the water purge. In the case of
an initial refrigeration start-up or auto
shut-off, they stay on for an additional
5 seconds (50 seconds total).
Remote - Water Purge
Table 6-8. Remote Models
SV3158-1
Water Valve
Harvest Valve
Dump Valve
Water Pump
(20)
(21)
(79)
(74)
(61)
(60)
(57)
(98)
(22)
(76)
(81)
(77)
(80)
(26)
(25)
(58)
(59)
Contactor Coil
(56)
L2
Air Compressor
(8)
(83)
(88)
(22)
(75)
Liquid Line
Solenoid
HPR Valve
(55)
(89)
(9)
(78)
(82)
(42)
(50)
(45)
(46)
(F2)
(F1)
(51)
Black
Red
Yellow
(L1)
(L1)
(L2)
(6)
(1)
(2)
Remote Fan Motor
Remote
Condenser
Run Capacitor
Contactor
Contacts
Compressor
Ice Thickness
Probe
Water Level
Probe
High Pressure
Cut-out
Ground
Run
Cap.
OFF
Clean
ON
Bin Switch
Trans
Fuse 7A
Control Board
(2)
(6)
(5)
(1)
(7)
(4)
PTCR
Low DC
Voltage
Plug
(99)
1. Water Purge (45 Seconds)
Toggle Switch ICE
Bin Switch Closed
Control Board Relays
#1 Water Pump ON
#2 Harvest Valve (Left) / HPR Valve ON
#3 Harvest Valve (Right) ON (When Used)
#4 Air Compressor 35 sec. OFF / 10 sec. ON
#5 Water Inlet Valve OFF
#6 Water Dump Valve ON
#7 Contactor Coil / Liquid Line Solenoid Open / OFF
#7A Compressor OFF
#7B Condenser Fan Motor OFF
Safety Controls (Which could stop ice machine operation)
High Pressure Cut-Out Closed
Main Fuse (On Control Board) Closed