68 Part Number 80-1479-3 7/10
Self Contained Air & Water-Cooled
Single Evaporator Model Energized Parts Chart
Ice Making
Sequence of
Operation
Water
Pump
Harvest
Valve(s)
Air
Pump(s)*
Water
Inlet
Valve
Water
Dump
Valve
Contactor
Coil
Compressor
Condenser
Fan Motor
Length
of Time
Start-Up
1. Water Purge
On On
35 sec.
Off
10 sec.
On
Off On Off Off Off
45 Seconds
2. Refrigeration
System Start-up
Off On Off On Off On On
May Cycle
On/Off
5 Seconds
Freeze Sequence
3. Prechill
Off Off Off
May
Cycle
On/Off
during
pre-chill
Off On On
May Cycle
On/Off
Initial Start-Up is
60 Seconds
30 Seconds thereafter
4. Freeze
On Off Off
Cycles
Off then
On one
more
time
Off On On
May Cycle
On/Off
Unil 10 Sec.
Water Contact
w/Ice Thickness Probe