EasyManuals Logo
Home>Manitowoc>Ice Maker>SD1402A

Manitowoc SD1402A User Manual

Manitowoc SD1402A
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #93 background imageLoading...
Page #93 background image
Part Number 80-1479-3 7/10 93
CHECK MOTOR WINDINGS TO GROUND
Check continuity between all three terminals and the
compressor shell or copper refrigeration line. Scrape
metal surface to get good contact. If continuity is
present, the compressor windings are grounded and
the compressor should be replaced.
COMPRESSOR DRAWING LOCKED ROTOR
To determine if the compressor is seized, check the
amp draw while the compressor is trying to start.
The two likely causes of this are a defective starting
component and a mechanically seized compressor.
To determine which you have:
1. Install high and low side gauges.
2. Try to start the compressor.
3. Watch the pressures closely.
A. If the pressures do not move, the compressor
is seized. Replace the compressor.
B. If the pressures move, the compressor is
turning slowly and is not seized. Check the
capacitors and relay.
COMPRESSOR DRAWING HIGH AMPS
The continuous amperage draw on start-up should not
be near the maximum fuse size indicated on the serial
tag.

Table of Contents

Other manuals for Manitowoc SD1402A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc SD1402A and is the answer not in the manual?

Manitowoc SD1402A Specifications

General IconGeneral
BrandManitowoc
ModelSD1402A
CategoryIce Maker
LanguageEnglish

Related product manuals