Part Number 000001590 Rev03 11/19 25
Section 4 Maintenance
WATER SHUTTERS
The water shutter is designed to keep the spraying water
from escaping the evaporator compartment.
TO REMOVE JUST THE WATER SHUTTERS:
1. Grasp one end of the water shutter and lift up.
2. Pivot water shutter and disengage remaining end.
3. To re-install into ice machine, grasp one end of the water
shutters, install one end, pivot the opposite end and
pull down into position. Make sure tabs are secure in
grooves.
TO REMOVE WATER SHUTTER ASSEMBLY:
1. Slide evaporator bucket forward 1/2” (13 mm).
2. Lift shutter assembly straight up.
n
Warning
Removing the water shutters while the water pump
is running will allow water to spray from ice machine.
Disconnect electrical power to the ice machine at the
electric service switch box and turn off the water supply.
ICE CHUTE
The ice chute is positioned over the spray nozzles and allows
the ice to easily fall into the bin. It must be firmly positioned
over the spray bar, with the front edge inside the water
trough. Spray nozzles must be align with the spray holes or
spray water will fall into the bin.
1. Grab protruding spray hole on one end and lift up and
remove.
2. To re-install ice chute, grasp protruding spray hole and
position over Water Distribution Assembly.
Make sure rear supports are over spray bar, and front edge is
inside of water trough.

Table of Contents

Other manuals for Manitowoc SMS050A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc SMS050A and is the answer not in the manual?

Manitowoc SMS050A Specifications

General IconGeneral
BrandManitowoc
ModelSMS050A
CategoryIce Maker
LanguageEnglish

Related product manuals