156 Part Number 000014797 Rev02 05/18
Determining Which Safety Limit Stopped the Ice Machine:
When a safety limit condition causes the ice machine to
stop, the harvest light on the control board continually
flashes on and off. Use the following procedures to
determine which safety limit has stopped the ice machine.
1. Move the toggle switch to OFF.
2. Move the toggle switch back to ON.
3. Watch the harvest light. It will flash one or two times,
corresponding to safety limits 1 and 2, to indicate
which safety limit stopped the ice machine.
After safety limit indication, the ice machine will restart
and run until a safety limit is exceeded again.
Safety Limit Notes
A continuous run of 100 harvests automatically erases
the safety limit code.
The control board will store and indicate only one
safety limit – the last one exceeded.
If the toggle switch is cycled OFF and then ON prior
to reaching the 100-harvest point, the last safety limit
exceeded will be indicated.