Part Number 000014797 Rev02 05/18 39
PREVENTATIVE MAINTENANCE CLEANING
This cleaning procedure can be performed between the bi-
annual cleaning and sanitizing cycles. This procedure does
not require removing the ice from the bin.
Step 1 Press the On/Off button after ice falls from the
evaporator at the end of a Harvest cycle. Or, press the On/
Off button and allow the ice to melt off the evaporator.
,
Caution
Never use anything to force ice from the evaporator.
Damage may result.
n
Warning
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner or Sanitizer.
Step 2 To start a cleaning cycle, press the Clean button.
Water will flow through the water dump valve and down
the drain. Wait until the water trough refills, then add the
proper amount of ice machine cleaner to the water trough.
Model Amount of Cleaner
U0140/UF0140 2 ounce (60 ml)
U0190/UF0190 5 ounces (150 ml)
U240/UF0240 5 ounces (150 ml)
U310/UF0310 5 ounces (150 ml)
Wait until the clean cycle is complete (approximately 22
minutes) then press the On/Off button.