Part Number 000014797 Rev02 05/18 161
Ice Machine Cycles Into Harvest Before Water Contact
with the Ice Thickness Probe
Step 1 Bypass the freeze time lock-in feature by
moving the ON/OFF/WASH switch to OFF and back to ON.
Wait until the water starts to flow over the evaporator,
then monitor the harvest light.
Step 2 Disconnect the ice thickness probe from the
control board terminal.
Step 2 Disconnect probe from control board terminal.
Monitoring Harvest Light Correction
The harvest light stays off and
the ice machine remains in the
freeze sequence.
The ice thickness probe is
causing the malfunction. Verify
that the Ice Thickness probe is
adjusted correctly.
The harvest light comes on,
and 6-10 seconds later, the ice
machine cycles from freeze to
harvest.
The control board is causing the
malfunction.