GSW1
USER MANUAL
Page 14
8.4 CALLER ID ACCESS
Caller ID access is a very simple way to control relay output defined in Caller ID output setting.
User will by calling in the GSW1 unit trigger defined output.
Settings for this function are found in the Caller id # tab.
Figure 6: WEB Server-Caller ID Access
General settings:
Caller ID security mode: Selecting Caller ID Disabled deactivates caller ID function all
numbers are restricted. Selecting Caller ID for specific users will limit the caller ID function
only to the numbers on the list. Selecting Caller ID always ON will allow all users that
know the number of the unit to open defined output. In last option the user doesn’t need to
be on the list to trigger the output
Caller ID output: Selecting the output that will be triggered in Caller ID function.
NOTE
Selection Caller ID always ON will allow anybody with the knowledge of the
unit number to trigger the output by calling the unit. Use this setting with
caution.