Checking for Leaks
Burner Connections
1. Make sure the regulator hose and valve connections are securely fastened to
the burner and the tank.
2
3
W WARNING: Failure to inspect this connection or follow these
instructions could cause a fire or an explosion which can cause
death, serious bodily injury or damage to property.
4. Please refer to diagram for proper installation (Figures 1 and 3
contact 1.800.963.0211 for assistance.
Tank / Gas Line Connection
1. Make 2-3 oz. of leak detection solution by mixing one part liquid dishwashing
soap with three parts water.
2. Make sure control knobs are in the “ OFF” position (Figure 3
3. Connect LP gas tank per “Installing LP Gas Tank” section.
4. Turn LP gas tank valve to “OPEN”.
. Spoon several drops of solution, or use a squirt bottle, at all “X” locations
(Figures 1, 2 and 4
a. If any bubbles appear, turn LP gas tank valve to “CLOSED”, reconnect and
re-test.
b. If you continue to see bubbles after several attempts, turn LP gas tank valve
to “CLOSED” and disconnect LP gas tank, per “Disconnecting LP Gas Tank”
section.
c. If no bubbles appear after one minute, turn LP gas tank valve to “CLOSED”,
wipe away solution and proceed.
Operating Main Burners
First Use
1. Make sure all labels, packaging and protective films have been removed
from the grill.
2. Remove manufacturing oils before cooking on this grill for the first time by
operating the grill for at least minutes on
This will “heat clean” the internal parts and dissipate odors.
Lighting
W CAUTION: Keep outdoor gas cooking appliance area clear and free
from combustible materials, gasoline and other flammable vapors
and liquids.
W CAUTION: Do NOT obstruct the flow of combustion and ventilation
air.
W CAUTION
insect nests. A clogged tube can lead to a fire.
W CAUTION: Attempting to light the burner with the lid closed may
cause an explosion.
1. Open lid.
2. Check for obstructions of airflow to the burners. Spiders, insects and webs can
3. All control knobs must be in the “ OFF” position (Figure 3
4. Connect LP gas tank per “Installing LP Gas Tank” section.
. Turn LP gas tank valve to “OPEN”.
6. Push and turn control knob to
times.
7. If ignition does not occur in seconds, turn burner control knob “ OFF,” wait
minutes, and repeat lighting procedure.
8. If igniter does not light burner, use a lit match secured with the lighting rod
near side of burner (Figure
9. After lighting, observe the burner flame. Make sure all burner ports are lit and flame height matches illustration
(Figure 6
Note: Each burner lights independently - repeat steps -9 for the other burners.
OPERATING INSTRUCTIONS
Figure 1 Main Burners
Venturi Tube
LP Gas Valve
LP Gas
Connection
Figure 2 Side Burner
LP Gas
Connection
Valve
Soft Pipe
Connection
Venturi
Tube
Figure 3
OFF
Figure 4
X
X
X
X
X
20