Pre-Treatment:
A complete water test is recommended to determine if pre-treatment
equipment is required before installation of the UV unit. Water must meet
criteria below:
Total Dissolved Solids (TDS)
If untreated water quality exceeds the maximum allowable levels
specified, this will result in bacteria passing through the UV unit and
into the piping system.
Unit Location:
1. The MWC-E unit must be installed after the well tank and any
water pre-treatment equipment (softeners, filter, etc.). You must
install a Cartridge type Dirt Filter before the MWC-E unit to
eliminate the possibility of a dirt build-up inside the stainless
steel sterilization chamber. (SEE PAGE 2, PIPING LAYOUT )
2. Install at least 4 feet from a dedicated electrical outlet.
DO NOT INSTALL NEAR ANY HEATING SYSTEMS WHICH
RAISE THE AIR TEMPERATURE OVER 100 DEGREES.