• Speed Errors & Resistance Errors are rarely related to console failures without an accompanying
error code or sensor hardware failure.
• To set resistance brake level 1 position, refer to Training Cycle Frame under Troubleshooting
Guides, or section 8.4 of the Service Manual.
• To read the Position Control Board output, find the “resistance_pos” value at the bottom of the
Hardware tab in 3001 Service Mode. Reference the following information:
o ‘resistance_pos” should increase with increasing resistance.
o Resistance Lever at upper stop (minimum resistance), ‘resistance_pos’ should read
approximately 10500 – 17500.
o Resistance Lever at lower stop (maximum resistance), ‘resistance_pos’ should read
approximately 10500 greater than the minimum.
o If ‘resistance_pos’ is 0 or greater than 30000, or does not change when the Resistance
Lever is moved, check all wiring connections & cables for damage before replacing parts.