5
ENGLISH
PRODUCT INFORMATION
PROPER USAGE
1. Do not exceed weight limits of the exercise device.
2. If applicable, set safety stops to appropriate height.
3. If applicable, adjust seat pads, leg pads, foot pads, range of motion
adjustment, or any other type of adjustment mechanisms to a comfortable
start position. Make certain that the adjusting mechanism is fully
engaged to prevent unintentional movement and to avoid injury.
4. Sit on bench (if applicable) and get into appropriate position for exercise.
5. Exercise using no more weight than you can safely lift and control.
6. In a controlled manner, perform exercise.
7. Return weight to its fully-supported start position.
MAINTENANCE CHECKLIST
ACTION FREQUENCY
Clean Upholstery
1
Daily
Inspect Cables
2
Daily
Clean Guide Rods Monthly
Inspect Hardware Monthly
Inspect Frame Bi-Annually
Clean Machine As Needed
Clean Grips
1
As Needed
Lubricate Guide Rods
3
As Needed
1
Upholstery & Grips should be cleaned with a mild soap
and water or a non-ammonia based cleaner.
2
Cables should be inspected for cracks or frays and immediately replaced if present.
If excessive slack exists cable should be tightened without lifting the head plate.
3
Guide rods should be lubricated with Teflon based lubricant. Apply the
lubricant to a cotton cloth and then apply up and down the guide rods.
TORQUE VALUES
M12 Bolt (Nyloc Nut & Flowdrill) 135 Nm / 100 ft-lbs
M10 Bolt (Nyloc Nut & Flowdrill) 77 Nm / 57 ft -lbs
M8 Bolts 25 Nm / 18 ft-lbs
M8 Plastic 15 Nm / 11 ft-lbs
M6 Bolts 15 Nm / 11 ft-lbs
Pad Bolts 10 Nm / 7 ft-lbs
PRODUCT SPECIFICATIONS
Max User Weight 159 kg / 350 lbs
Max Training Weight 91 kg / 200 lbs
Product Weight 120 kg / 265 lbs
Overall Dimensions
(L x W x H)*
135 x 109 x 245 cm /
53 x 43 x 96”
* Ensure a minimum clearance width of 0.6 meters (24”) for access to and
passage around MATRIX strength equipment. Please note, 0.91 meters (36”)