EasyManuals Logo
Home>Matrix>Exercise Bike>R7X-03

Matrix R7X-03 User Manual

Matrix R7X-03
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
45
9.9 HEART RATE GRIPS REPLACEMENT
CHAPTER 9: PART REPLACEMENT GUIDE
1) Remove the 3 screws holding the HR grip together (Figure A).
2) Once the 3 screws are removed, the HR grip can be split into 2 pieces (Figure B).
3) Disconnect the keypad / overlay and the HR plate wiring and remove the old HR grip (Figure C).
4) Reverse Steps 1-3 to install new HR grips. The white wire should be on the back side HR plate, the red wire on the front. Make sure that
the end cap also gets installed (Figure D).
5) Test the Bike for function as outlined in Section 9.23.
FIGURE A FIGURE B
FIGURE C
FIGURE D

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Matrix R7X-03 and is the answer not in the manual?

Matrix R7X-03 Specifications

General IconGeneral
BrandMatrix
ModelR7X-03
CategoryExercise Bike
LanguageEnglish

Related product manuals