Troubleshooting Procedures
CAUTION
!
To avoid electrical shock, personal injury, or death, disconnect power to unit before servicing, unless testing
requires power.
©2005 Maytag Services
16026267 17
Temperature in
the oven cavity
is lower or higher
than present.
Abnormal
Normal
Check the relay
4 of P.C.B.
assembly.
Abnormal
Normal
Failed
convection heater.
Replace
convection heater.
Check the
convection heater
element.
Abnormal
Normal
Failed
circulation motor.
Replace
circulation motor.
Check the
circulation motor.
Abnormal
Normal
Failed
damper motor.
Replace
damper motor.
Check the
damper motor.
Interference
damper open
and close at air
duct assembly.
Normal
Failed air
duct assembly.
Replace air duct
assembly.
Check the air
duct assembly.
Error message
shows in the
display.
Normal
Thermistor open
or short.
Replay
thermistor.
Check the
thermistor.
Cook on the
glass tray.
Without
metal rack.
Cook with
metal rack.
Check the rack.
Convection indicator
light but oven does
not go into cook
cycle when START
pad is touched.
Abnormal
Normal
No continuity.
Loose connection.
Connect them
tightly.
Failed relay 4.
Replace P.C.B.
assembly.
Check the relay
4 of P.C.B.
assembly.
Check the
connection between
P.C.B. assembly
and headwire
connector.
CONDITION CHECK RESULT CAUSE REMEDY
(TROUBLE 6)
Convection oven does not operate at all or convection cook is bad.
Replace P.C.B.
assembly.
Failed relay 4.