R410A 60Hz 16 SEER Universal Outdoor Series Technical Manual
17
5. Electric Characteristics
Model
Outdoor Unit
Hz
Voltage
Min.
Max.
Outdoor
motor
output(kw)
MCI16036CCU216A
60
208~230V
198V
242V
0.21
MCI16060CCU216A
60
208~230V
198V
242V
0.36
6. Operation Limits
Operation mode
Outdoor temperature()
Room temperature()
Cooling operation
18~47
16~32
10 15 25 30 3520
15
20
25
30
35
40
45
Indoor temperature( WB)
Outdoor temperature(
DB)
STD
Cooling