9. BR20 Standard Format Code Summary:
The following formats are supported in standard models (31002-8000/31012-8000).
Unless otherwise indicated, the LED input line controls both LEDs (low=green, high=red); the BUZZER input
controls the buzzer (low = activate); a good read is signaled by a flash of the green LED; a bad read is signaled
by a flash of the red LED and a double beep of the buzzer.
Format 0 - 32-bit Wiegand compatible output from standard Northern Computer mag card. 16-bit facility code
and 16-bit user ID. Reverse read and error filter is enabled. Tamper monitor disabled.
Format 1 - Basic mag-stripe data output: send track 2 data without any verification or formatting using CLOCK/
DATA signaling. All reads are "good", card data sent as is. Tamper monitor disabled.
Format 2 - Mag-stripe data output with zero trim using CLOCK/DATA signaling. All reads are "good", trims
excess zero bits, otherwise send data as is. Tamper monitor enabled.
Format 3 - Mag-stripe data output with zero trim, reverse read correction, and error filter enabled using CLOCK/
DATA signaling. Tamper monitor disabled.
Format 4 - 26-bit Wiegand (8-bit fac. and 16-bit ID) compatible output from cards with 8 or more digits or AMC
encoding. See Format 5 for digit usage. Tamper monitor disabled.
Format 5 - 34-bit Wiegand (12-bit fac. and 20-bit ID) compatible output from cards with 8 or more digits or AMC
encoding. Tamper monitor disabled.
Facility Code User ID
Digits in mag card Digits 26-bit Range 34-bit Range Digits 26-bit Range 34-bit Range
8 1-3 000-255 000-999 4-8 00000-65535 00000-99999
9 1-3 000-255 000-999 4-9 000000-065535 000000-999999
10 1-4 0000-0255 0000-4097 5-10 000000-065535 000000-999999
11 or more 1-5 00000-00255 00000-04097 6-11 000000-065535 000000-999999
AMC card 1-6 000000-000255 000000-004097 7-12 000000-065535 000000-999999
Format 6 - 26-bit Wiegand compatible output from standard Northern Computer 32-bit mag-stripe card. The lower
8 bits of the 16-bit facility code is used as facility code. The 16-bit user ID is unaltered. Reverse read
and error filter is enabled. Tamper monitor disabled
Format 7 - Mag-stripe data output with zero trim and reverse read correction using DATA 1/DATA 0 signaling.
Tamper monitor disabled.
Format 12 - Mag-stripe data output: send track 2 data without any verification or formatting using CLOCK/DATA.
All reads are "good", card data is sent as is. 2-wire LED control. No buzzer control. Tamper monitor
disabled.
Format 13 - Mag-stripe data output with zero trim and reverse read correction using DATA 1/DATA 0 signaling.
2-wire LED control. No buzzer control. Tamper monitor disabled.
Format 15 - (factory test) mag-stripe data output: verify track 2 data and send track 2 data without formatting using
CLOCK/DATA signaling. Zero trim, reverse read, bad card filter, and tamper monitor enabled.
10. Keypad Data Signaling:
Keypad data is transmitted on the data lines as 8-bit blocks. They are encoded and sent using the same signaling
method as selected for the card data output (clock/data or data 1/data 0). If Dorado 8-bit keypad data format is required
order the -K1 option. Card data, and keypad data blocks are separated by a minimum of 100 milliseconds. See following
for codes:
10110000 - 0 (ASCII '0', odd parity, MSB first) 00110001 - 1 (ASCII '1', ...)
00110010 - 2 (ASCII '2', ...) 10110011 - 3 (ACSII '3', ...)
00110100 - 4 (ASCII '4', ...) 10110101 - 5 (ASCII '5', ...)
10110110 - 6 (ASCII '6', ...) 00110111 - 7 (ASCII '7', ...)
00111000 - 8 (ASCII '8', ...) 10111001 - 9 (ASCII '9', ...)
00101010 - * (ASCII '*', ...) 00100011 - # (ASCII '#', ...)
11010011 - SAFE (ASCII 'S', ...) 01010100 - ALARM (ASCII 'T', ...)
Question and Answer IconNeed help?

Do you have a question about the Mercury BR20 and is the answer not in the manual?

Mercury BR20 Specifications

General IconGeneral
BrandMercury
ModelBR20
CategoryDoor locks
LanguageEnglish

Summary

Mounting the Reader

Reader Wiring

Connecting the Keypad

TTL Interface

DIP Switch Setting

BR20 Standard Format Code Summary

Keypad Data Signaling

Reader Verification

Maintenance

Specifications

Product Identification

Reader Mounting Dimensions

Warranty