SMARTCRAFT CONNECT GATEWAY INSTALLATION MANUAL
Page 8 / 10 © 2021 Mercury Marine 90-8M0184941 eng JUNE 2021
14.
Enter the correct information for the Engine Type, and Engine Model. Review your selections, and if everything is
correct, select Save.
15. Continue by entering the engine serial number for the engine(s) supported by the module.
16. Next, configure the CAN H connection by following the prompts on the screen.
NOTE: CAN H configuration only applies to boats with steer‑by‑wire systems; Joystick Piloting, outboard, sterndrive, or
Zeus. If the boat is DTS or Non‑DTS, the CAN H gateway should be disabled.
17. Verify that the Wi‑Fi LED is solid, indicating that the device has completed a cloud sync. If this is not verified, there is no
certainty that the configuration was delivered to the module.
Troubleshooting
LED Lighting
The device contains 5 LEDs for indicating the status of CAN P, NMEA, CAN H, Wi‑Fi, and Bluetooth®.
1.
CAN P
•
Flashing: The LED will flash continuously once power is applied.
•
Solid: Once the bus communication is established, the LED will remain on.
2.
NMEA
•
Flashing: The LED will flash continuously once power is applied.
•
Solid: Once the bus communication is established, the LED will remain on.
3.
CAN H
NOTE: The CAN H LED will flash on any module connected to a mechanical engine, even if the CAN H BUS is disabled
in the SmartCraft Manager.
•
Flashing: The LED will flash continuously once power is applied.
•
Solid: Once the bus communication is established, the LED will remain on.
4.
Wi‑Fi
•
Off: No connection.
•
Flashing: Connected to a Wi‑Fi access point. Attempting to sync with the Mercury cloud server.
•
On: Connected to a Wi‑Fi access point and synced with the Mercury cloud server.
5.
Bluetooth
•
Flashing: The Bluetooth LED will flash while in pairing mode, indicating it is not currently connected.
•
Solid: The Bluetooth LED will remain on continuously while connected.
SmartCraft CONNECT Module NMEA 2000 Information
The software is capable of transmitting (TX) information to, and receiving (RX) information from various parameter group
number (PGN) products.
NMEA 2000 Network Power Information
Value
NMEA 2000 Load Equivalency Number (LEN) 1