Portable 2000 count digital multimeter
19
3. FUNCTION DESCRIPTION
3.1
AC or DC voltages
• Connect the leads to the multimeter (COM and V terminals)
and
connect it in parallel to the circuit to be tested.
•
Position the selector sw
itch on the voltmeter function « V or mV ».
• Automatic range selection : read the measured value.
•
Memorise it, if necessary, by pressing the « MEM » key.
• Overload : the beep sounds and « 1
» blinks.
• Specification in AC : from 5 % of the range.
3.1.1 mV
DC
and mV
AC
positions
Range
20 mV
DC
200 mV
AC
Resolution 0.01 mV 0.1 mV
Impedance
5 MΩ
3
MΩ
Accuracy ± 1.5 % R ± 5 digits ± 2 % R ± 15 digits
Protection 600 Vrms
Bandwidth DC 40 Hz to 100 Hz
3.1.2 V
DC
and V
AC
positions
Range
200 mV (∗)
2 V 20 V 200 V 600 V
Resolution 0.1 mV 1 mV 10 mV 0.1 V 1 V
Impedance
5 MΩ
Accuracy
DC
± 1 % R ± 4 digits
Accuracy
AC
- ± 1.5 % R ± 8 digits
Protection 600 Vrms
Bandwidth
DC
DC : 40 Hz to 500 Hz
(∗) in VDC only
3.2 Resistance
• Connect the leads to the multimeter (COM and Ω
terminals) and to
the circuit or the component to be tested.
•
Position the selector switch on the ohmmeter function « Ω ».
• Automatic range selection : read the measured value.
•
Memorise the value, if necessary, by pressing the « MEM » key.
• Overload : the beep sounds and « 1
» blinks.
• IΩ : <
0.4 mA
Range
200 Ω 2 kΩ 20 kΩ 200 kΩ 2000 kΩ 20 MΩ
Resolution
0.1 Ω 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ
Accuracy ± 1 % R ± 4 digits
± 1.5 % R
± 4 digits
± 3 % R
± 4 digits
Voltage on
open circuit
< 2 V
Protection 600 Vrms
Never test a resistance on a live circuit.