CAUTION: Risk of injury!
Before installing this water heater,check and confirm that the earthing on the supply
socket is reliably grounded. Otherwise, the electrical water heater can not be installed
and used. Do not use extension boards. Incorrect installation and use of this electrical
water heater may result in serious injuries and loss of property.
Special Cautions
The supply socket must be earthed reliably. The rated current of the socket shall not
be lower than 16A. The socket and plug shall be kept dry to prevent electrical leakage.
The installation height of the supply socket shall not be lower than 1.8m.
The wall in which the electrical water heater is installed shall be able to bear the load
more than two times of the heater filled fully with water without distortion and cracks.
Otherwise, other strengthening measures shall be adopted.
The pressure relief valve attached with the heater must be installed at the cold water
inlet of this heater(see Fig.1), and make sure it is not exposed in the foggy. The water
may be outflowed from pressure relief valve, so the outflow pipe must open wide in
the air; The pressure relief valve need to be checked and cleaned regularly, so as to
make sure it will not be blocked.
When using the heater for the first time(or the first use after maintenance), the heater
can not be switched on until it has been filled fully with water. When filling the water,
at least one of the outlet valves at the outlet of the heater must be opened to exhaust
the air. This valve can be closed after the heater has been filled fully with water.
The water heater is not intended for use by persons(including children)with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instructions concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they
do not play with the heater.
During heating, there may be drops of water dripping from the pressure release hole
of the pressure relief valve. This is a normal phenomenon. If there is a large amount of
water leak, please contact customer care center for repair. This pressure release hole
shall, under no circumstances, be blocked; otherwise, the heater may be damaged,
even resulting in accidents.
Hot water
Cold water
(Fig.1)
Pressure relief valve
Thread screw
Drain handle
Pressure release hole
Sewerage exit

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea HORIZONTAL Series and is the answer not in the manual?

Midea HORIZONTAL Series Specifications

General IconGeneral
BrandMidea
ModelHORIZONTAL Series
CategoryWater Heater
LanguageEnglish

Related product manuals