3.3 Selecting an installation location
The solar kit is to be installed in a frost free indoor space, directly connected to the sanitary hot
water tank.
Make sure the service space is available.
The space around the unit has to allow sufficient air circulation.
It shall be made sure that in the case of a leak, leaking water will not cause any damage or
unsafe situations.
Do not install or operate the unit in rooms mentioned below:
Where corrosive gas like sulphurous gas exists: copper tubing and brazed spots may
corrode.
Where volatile flammable gas like thinner or gasoline is used.
Where machines generating electromagnetic waves exist the control system may
malfunction.
Where the air contains high levels of salt such as air near the ocean and where voltage
fluctuates a lot (e.g. in factories).This applies also to vehicles or vessels.
3.4 Dimensions and service space
Service space dimensions below relate to requirements for installation of the solar kit only.
3.5 Installation guidelines
Make sure that all the piping to the solar kit is insulated.
Make sure that all the piping to the solar kit is sufficiently supported so that it will not cause any
stress on the solar kit.
Make sure that the piping coming from outdoors to the solar kit is put through the wall under an