Service manual
- 3 -
2. Function
The function will be
operate in any operation
Indoor unit
Operation ON/OFF by remote controller
Room temperature sensor.
Pipe temperature sensor.
Sensing by room temperature
Maintain the room temperature in accordance with the setting temperature.
Room temperature control
Indoor fan is delayed for 5 sec at the starting.
Starting temperature control
Restarting is for approx. 3 minutes..
Time Delay Safety control
High, med, low, breeze.
Indoor fan speed control
Light up in the LED (LCD) for each operation mode.
The unit will decide the louver direction according to operation mode.
Two-direction air vane
The fan is turn to low speed (cooling/heating).
The unit will be turn off after seven hours.
Sleep mode auto control
The function is usually used in rainy days in
springtime or damp areas.
Independent dehumidification
Operation indication Lamps (LED)
The louver can be set at the desired position or swing up and
down automatically
Air flow Direction control
The unit can be change by the room temperature.
Auto mode
Easy clean panel
Flexible wiring connection
Defrost mode
Temp. Compensation
Prevent the cold wind at
the beginning of unit start.
Anti-cold function
Auto-restart function
Self-diag. function