Issue Possible Causes
Air movement sound. This is normal. If too loud, turn selector to lower FAN setting.
Sound of fan hitting water-moisture removal system. This is normal when humidity is high.
Close doors, windows and registers.
Window vibration - poor installation. Refer to installation instructions or check with installer.
Improper installation. Tilt air conditioner slightly to the outside to allow water drainage.
Refer to installation instructions - check with installer.
Unit removing large quantity of moisture from humid room. This is normal during excessively humid days.
Noise when unit is
cooling
Water dripping INSIDE
when unit is cooling
Water dripping OUTSIDE
when unit is cooling
Unit dimensions: Choose the right cable size
MODEL(But/h)
Note: For the different customization requirements,
the deepth of the panel may be slightly different. So
the dimension of “D” is for reference only.
5000~6000
445x320x415
450x346x535
450x346x535
450x346x585
450x346x585
560x400x640
600x380x560
660x428x680
660x428x780
7000~9000
9000~12000
15000~24000
BODY DIMENSION(WxHxD)(mm)
SPECIFICATIONS
Minimum norminal cross-sectional area of conductors:
The size of the power supply cable, signal cable, fuse, and switch needed is determined by the
maximum current of the unit. The maximum current is indicated on the nameplate located on
the side panel of the unit. Refer to this nameplate to choose the right cable, fuse, or switch.
Rated Current of Appliance (A) Nominal Cross-Sectional Area (mm²)
> 3 and ≤ 6 0.75
1
1.5
2.5
4
6
NOTE: TO be in compliance EN61000-3-11, the product MWT2F-21CM-QB4 shall be conn-
ected only to a supply of the system impedance: |Zsys|=0.156 ohms or less; the product
MWT2F1-22CM-QB4 shall be connected only to a supply of the system impedance: |Zsys|=0.132
ohms or less;the product MWT2F1-22CM-QB8 shall be connected only to a supply of the
system impedance: |Zsys|=0.077 ohms or less. Before connect the product to public power
network, please consult your local power supply authority to ensure the power network meet
above requirement.
> 32 and ≤ 40
> 25 and ≤ 32
> 16 and ≤ 25
> 10 and ≤ 16
> 6 and ≤ 10