All electrical work should be
performed by a qualified electrician
in strict accordance with national
and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer is not
responsible for unauthorized work.
Ensure that power to the appliance
is OFF while installation or repair
work is performed.
Verify that the voltage, load and circuit
rating information found on the data
plate (located behind the grease
filters), match the household electrical
supply before installing the hood.
If there is any question concerning the
electrical connection of this appliance
to your power supply, please consult a
licensed electrician or Miele’s Technical
Service.
USA 1-800-999-1360
CDN 1-800-565-6435
WARNING:
THIS APPLIANCE MUST BE
GROUNDED
Important
The hood must be hard wired
accordingly:
Black/Red wire:. . . . connect to L1 (live)
White wire: . . . . . connect to N (neutral)
Green wire: . . connect to GND (ground)
Maximum load. . . . . . . . . . . . . . . 450 W
Overhead lighting . . . . . . . . . . 4 x 20 W
Indirect lighting . . . . . . . . . . . . 2 x 10 W
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V
Frequency . . . . . . . . . . . . . . . . . . 60 Hz
Circuit rating. . . . . . . . . . . . . . . . . . 15 A
Electrical data