2.2 Range of usage & limitations
Indoor return air temperature
(Upper, lower limits)
Refrigerant line (one way) length Max. 15m
All models
Power source voltage Rating ± 10%
Voltage at starting Min. 85% of rating
Frequency of ON-OFF cycle
ON and OFF interval Max. 3 minutes
Outdoor air temperature
(Upper, lower limits)
Vertical height difference between
outdoor unit and indoor unit
Max. 5m (Outdoor unit is higher)
Max. 5m (Outdoor unit is lower)
Item
Models
Max. 10 times/h
(Inching prevention 3 minutes)
Cooling operation : Approximately 21 to 32˚C
Heating operation : Approximately 15 to 30˚C
Cooling operation : Approximately 21 to 43˚C
Heating operation : Approximately -5 to 21˚C
2.3 Exterior dimensions
(1) Indoor unit
Models All models
Piping hole (ø65)
( )
Piping hole (ø65)
53.5
380.6
Pipng for Liquid 448.6 (ø6.35)
20, 28 : ø9.52
40 : ø12.7
Pipng for Gas
Drain hose 520 (ø16)
53.5
44.5
252.2
7.5
8.3
102.5
585
102.5
133.5450206.5
202450138
44.5
43.2
39.3
200
45
45
60
17.5
60
27
788
60
9
45
199
3
Terminal block
Piping hole right(left)
268
790
A
VIEW A
®
Unit: mm

Other manuals for Mitsubishi Heavy Industries SRK20HG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SRK20HG and is the answer not in the manual?

Mitsubishi Heavy Industries SRK20HG Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSRK20HG
CategoryAir Conditioner
LanguageEnglish

Related product manuals