SRK25ZJP-S,35ZJP-S SRK50ZJP-S
Net capacity = Capacity shown on specification Correction factors as follows.
(1) Coefficient of cooling and heating capacity in relation to temperatures
Cooling
Heating
2220181614
0.6
0.7
0.8
0.9
1.0
1.2
1.1
1.3
0
-5
-10
-15
Applicable range
Depends on installed situation
24
26
20
25
30
35
40
46
10
15
20
25
27
Outdoor air W.B. temperature
(°C W.B.)
-15 -10 -5 0 5 10 15
ISO-T1 Standard Condition
Cooling operation
Outdoor air D.B.
temperature
(°C D. B.)
Coefficient of cooling
&
Heating capacity in
relation to temperature
Heating operation
Indoor air D.B.
temperature
(°C D. B.)
ISO-T1 Standard Condition
Indoor air W.B. temperature °C W.B.
+
7