'10 • SRK-T-100
(5) Flap control
Control the ap by AIRFLOW
(UP/DOWN) button on the wireless remote controller.
(a) Flap
Each time when you press the AIRFLOW
(UP/DOWN) button the mode changes as follows.
(b) Swing
Flap moves in upward and downward directions continuously.
(c) Memory flap
When you press the AIRFLOW (UP/DOWN) button once while the ap is operating, it stops swingingat an angle. Since this
angle is memorized in the microcomputer, the ap will automatically be set at this angle when the next operation is started.
(d) When not operating
The ap returns to the position of air ow directly below, when operation has stopped.
COOL , DRY
Remote controller
display
HEAT
Angle of flap from horizontal
Approx. 10°
Approx. 20°
Approx. 20°
Approx. 35°
Approx. 30°
Approx. 50°
Approx. 45°
Approx. 60°
Approx. 60°
Approx. 75°
(Swing)
(Flap stopped)
SIn HEAT operation SIn COOL, DRY operation
Approx. 30°
Approx. 75°
Approx.
10°
Approx. 60°
(b) Sleep timer operation
Pressing the SLEEP button causes the temperature to be controlled with respect to the set temperature.
(6) Timer operation
(a) Comfortable timer setting (ON timer)
(c) OFF timer operation
The Off timer can be set at a specic time (in 10-minute units) within a 24-hour period.
If the timer is set at ON when the operation select switch is set at the cooling or heating, or the cooling or heating in auto mode
operation is selected, the comfortable timer starts and determines the starting time of next operation based on the initial value of 15
minutes and the relationship between the room temperature at the setting time (temperature of room temperature sensor) and the
setting temperature.