EasyManuals Logo
Home>Mitsubishi>Controller>FX3U Series

Mitsubishi FX3U Series Hardware Manual

Mitsubishi FX3U Series
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
FX3U SERIES PROGRAMMABLE
CONTROLLERS
HARDWARE MANUAL
This manual describes the part names, dimensions, mounting,
cabling and specifications for the product. This manual is extracted
from FX3U Series User's Manual - Hardware Edition. Refer to FX3U
Series User's Manual - Hardware Edition for more details. Before
use, read this manual and manuals of relevant products fully to
acquire proficiency in the handling and operating the product. Make
sure to learn all the product information, safety information, and
precautions.
And, store this manual in a safe place so that you can take it out and
read it whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this
manual are the registered trademarks or trademarks of each
company.
Effective Nov. 2008
Specifications are subject to change without notice.
© 2005 Mitsubishi Electric Corporation
Safety Precaution (Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and .
Depending on the circumstances, procedures indicated by
may also cause severe injury.
It is important to follow all precautions for personal safety.
.
Marine standard
Please consult with Mitsubishi Electric for the information on marine
standard practices and the corresponding types of equipment.
Manual Number JY997D18801
Revision G
Date November 2008
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
STARTUP AND
MAINTENANCE
PRECAUTIONS
Do not touch any terminal while the PLC's power is on.
Doing so may cause electric shock or malfunctions.
Before cleaning or retightening terminals externally cut off all
phases of the power supply.
Failure to do so may cause electric shock.
Make sure to connect the battery for memory backup correctly.
Do not charge, disassemble, heat, short-circuit, or expose the
battery to fire.
Doing so may rupture or ignite it.
Before modifying or disrupting the program in operation or
running the PLC, carefully read through this manual and the
associated manuals and ensure the safety of the operation.
An operation error may damage the machinery or cause accidents.
STARTUP AND
MAINTENANCE
PRECAUTIONS
Turn off the power to the PLC before attaching or detaching the
memory cassette. If the memory cassette is attached or
detached while the PLC's power is on, the data in the memory
may be destroyed, or the memory cassette may be damaged.
Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric distributor.
Turn off the power to the PLC before connecting or disconnecting
any extension cable.
Failure to do so may cause equipment failures or malfunctions.
Turn off the power to the PLC before attaching or detaching the
following devices.
Failure to do so may cause equipment failures or malfunctions.
- Display module, peripheral devices, expansion boards, and
special adapters
- Connector conversion adapter, extension blocks, and FX
Series terminal blocks
- Battery and memory cassette
DISPOSAL
PRECAUTIONS
Please contact a certified electronic waste disposal company
for the environmentally safe recycling and disposal of your
device.
TRANSPORT AND
STORAGE
PRECAUTIONS
Before transporting the PLC, turn on the power to the PLC to
check that the BATT LED is off.
If the PLC is transported with the BATT LED on or the battery
exhausted, the battery-backed data may be unstable during
transportation.
The PLC is a precision instrument. During transportation, avoid
impacts larger than those specified in Section 2.1. Failure to do
so may cause failures in the PLC.
After transportation, verify the operations of the PLC.
Certification of UL, cUL standards
FX3U main units and input/output extension units/blocks supporting
UL, cUL standards are as follows:
UL, cUL file number :E95239
Models : MELSEC FX3U series manufactured
FX3U-ËËMR/ES(-A) FX3U-ËËMT/ES(-A)
FX3U-ËËMT/ESS
Where ËË indicates:16,32,48,64,80,128
FX3U-ËËMR/DS FX3U-ËËMT/DS
FX3U-ËËMT/DSS
Where ËË indicates:16,32,48,64,80
FX3U-232ADP FX3U-485ADP
FX3U-4AD-ADP FX3U-4DA-ADP
FX3U-4AD-PT-ADP FX3U-4AD-TC-ADP
FX3U-4HSX-ADP FX3U-2HSY-ADP
Models : MELSEC FX2N series manufactured
FX2N-ËËER-ES/UL FX2N-ËËET-ESS/UL
Where ËË indicates:32,48
FX2N-48ER-DS FX2N-48ET-DSS
FX2N-48ER-UA1/UL
FX2N-8ER-ES/UL FX2N-8EX-ES/UL
FX2N-8EYR-ES/UL FX2N-8EYT-ESS/UL
FX2N-8EX-UA1/UL
FX2N-16EX-ES/UL FX2N-16EYR-ES/UL
FX2N-16EYT-ESS/UL
Compliance with EC directive(CE Marking )
This document does not guarantee that a mechanical system
including this product will comply with the following standards.
Compliance to EMC directive and LVD directive of the entire
mechanical system should be checked by the user / manufacturer.
For more details please contact the local Mitsubishi Electric sales
site.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct
testing (of the identified standards below) and design analysis
(through the creation of a technical construction file) to the European
Directive for Electromagnetic Compatibility (89/336/EEC) when used
as directed by the appropriate documentation.
Type : Programmable Controller (Open Type Equipment)
Models : MELSEC FX3U series manufactured
from May 1st, 2005 FX3U-ËËMR/ES(-A)
Where ËË indicates:16,32,48,64,80
FX3U-4HSX-ADP FX3U-2HSY-ADP
FX3U-FLROM-16 FX3U-FLROM-64L
FX3U-7DM
from June 1st, 2005 FX3U-232ADP FX3U-485ADP
FX3U-4AD-ADP FX3U-4DA-ADP
FX3U-4AD-PT-ADP FX3U-4AD-TC-ADP
FX3U-232-BD FX3U-422-BD
FX3U-485-BD FX3U-USB-BD
FX3U-FLROM-64 FX3U-CNV-BD
from November 1st, 2005 FX
3U-ËËMT/ES(-A)
FX
3U-ËËMT/ESS
Where ËË indicates:16,32,48,64,80
from February 1st, 2006 FX
3U
-128MR/ES(-A) FX
3U
-128MT/ES(-A)
FX3U-128MT/ESS
FX
3U
-
ËË
MR/DS FX
3U
-
ËË
MT/DS
FX3U-ËËMT/DSS
Where ËË indicates:16,32,48,64,80
Models : MELSEC FX2N series manufactured
from July 1st, 1997 FX2N-ËËER-ES/UL FX2N-ËËET-ESS/UL
Where ËË indicates:32,48
FX2N-16EX-ES/UL FX2N-16EYR-ES/UL
FX2N-16EYT-ESS/UL
from April 1st, 1998 FX2N-48ER-DS FX2N-48ET-DSS
from August 1st, 1998 FX2N-48ER-UA1/UL
from August 1st, 2005 FX2N-8ER-ES/UL FX2N-8EX-ES/UL
FX2N-8EYR-ES/UL FX2N-8EYT-ESS/UL
For the products above, PLCs manufactured
before March 31st, 2002 are compliant with EN50081-2 (EN61000-
6-4) and EN50082-2
from April 1st, 2002 to April 30th, 2006 are compliant with EN50081-
2 (EN61000-6-4) and EN61131-2:1994+A11:1996+A12:2000
after May 1st, 2006 are compliant with EN61131-2:2003
Standard Remark
EN61131-2:2003
Programmable controllers
-Equipment
requirements and tests
Compliance with all relevant aspects
of the standard.
Radiated Emissions
Mains Terminal Voltage Emissions
RF immunity
Fast Transients
ESD Surge
Voltage drops and interruptions
Conducted
Power magnetic fields
Standard Remark
EN61000-6-4:2001
- Generic emission
standard
Industrial environment
EN50081-2:1993
Electromagnetic
compatibility
Compliance with all relevant aspects
of the standard.
Radiated Emissions
Mains Terminal Voltage Emissions
EN50082-2:1995
Electromagnetic
compatibility
- Generic immunity
standard
Industrial environment
Compliance with all relevant aspects
of the standard.
RF immunity
Fast Transients
ESD
Conducted
Power magnetic fields
EN61131-2:1994
/A11:1996
/A12:2000
Programmable controllers
-Equipment
requirements and tests
Compliance with all relevant aspects
of the standard.
RF Immunity
Fast Transients
ESD
Damped oscillatory wave
EN61131-2:2003
Programmable controllers
-Equipment
requirements and tests
Compliance with all relevant aspects
of the standard.
Radiated Emissions
Mains Terminal Voltage Emissions
RF immunity
Fast Transients
ESD Surge
Voltage drops and interruptions
Conducted
Power magnetic fields
JY997D18801G(ENGLISH)

Other manuals for Mitsubishi FX3U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3U Series and is the answer not in the manual?

Mitsubishi FX3U Series Specifications

General IconGeneral
BrandMitsubishi
ModelFX3U Series
CategoryController
LanguageEnglish

Related product manuals