SPECIFICATION
6
3
Indoor model
Function
Power supply
Capacity
Dehumidification
Air flow
(High/Med. /Low )
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Fan motor current
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Air direction
Sound level(High/Med. /Low )
Fan speed(High/Med. /Low )
Fan speed regulator
Thermistor RT11(at25:)
Thermistor RT12(at25:)
Outdoor model
Air flow(High/Low )
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at20:)
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Sound level(High)
Fan speed(High/Low )
Fan speed regulator
Refrigerant filling
capacity(R22)
Refrigerating oil (Model)
Thermistor RT61(at0:)
Thermistor RT63(at0:)
kW
r/h
K /h
A
A
W
A(kW)
%
A
A
"
mm
kg
dB
rpm
k"
k"
K /h
A
A
W
"
"
mm
kg
dB
rpm
kg
cc
k"
k"
MSH-18RV -
E1
Single phase
220-240V, 50Hz
756/654 /546
15
—
98-96
52-58
0.25
RA4V27-EF
WHT-BLK 183.8
BLK-RED 250.5
1,015O320O190
14
5
42/39 /34
1,180/1,040 /900
3
10
10
MUH-18RV -
E1
E2
High:2,142-2,244
0.39
PH-36VPET
1,600
C-R 1.03
C-S 2.04
RA6V50-OG
WHT-BLK 116.4
BLK-RED 111.0
850o605o290
54
52
High:810-845
1
1.65
900 (MS32N1)
33.18
—
Cooling
5.1
2.5
9.4-9.2
2,030-2,120
2.51-2.41
8.76-8.56
Heating
5.4
—
9.2-9.0
1,980-2,070
2.73-2.61
8.56-8.36
MSH-24RV -
E1
Single phase
220-240V, 50Hz
816/726 /630
25
—
98
59
0.29
RA4V27-EE
WHT-BLK 183.3
BLK-RED 250.5
1,015O320O190
14
5
45/42 /38
1,260/1,140 /1,020
3
10
10
MUH-24RV -
E1
2,640-2,760/2,100-2,250
0.58
NH-47VMDT
2,200
C-R 0.96
C-S 2.07
RA6V85-AA
WHT-BLK 62.7 BLK-YLW 30.2
YLW-RED 62.9
870o850o295
72
53
720-750/570-610
2
2.40
1,200 (MS32N1)
33.18
33.18
Cooling
6.0
3.1
12.6-11.7
2,720-2,750
2.21-2.18
11.73-10.83
Heating
6.2
—
11.5-11.0
2,470-2,580
2.51-2.40
10.63-10.13
Electrical
data
Fan
motor
Special
remarks
Compressor
Electrical
data
Fan
motor
Special
remarks
Capacity
Coefficient of performance(C.O.P)
Capacity
MSH-18RV -
E1
Single phase
220-240V, 50Hz
—
—
756/654 /546
10
0.28
60
—
97-89
—
0.25
—
RA4V27-EF
WHT-BLK 183.8
BLK-RED 250.5
1,015O320O190
14
5
42/39 /34
1,180/1,040 /900
3
10
10
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Cooling
Heating
w1.
ww
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
w
ww
w
w
w
w
W1.Refer to the Service Manual OB185 REVISED EDITION C when MSH-18RV- is connected with
MXZ-32NV- or MXZ-32NV- as multi system units.
Refer to the Service Manual OB227 REVISED EDITION-B when MSH-18RV- is connected with
MXZ-32RV- as multi system units.
Refer to the Service Manual OB254 when MSH-18RV- is connected with MXZ-32SV- as multi system units.
E1E1
E1
E1
E2E1
E1
NOTE: Test conditions are based on JIS C 9612.
Cooling : Indoor DB27°C WB19°C Heating : Indoor DB20°C WB 15.5°C
Outdoor DB35°C WB(24°C) Outdoor DB 7°C WB 6°C
Indoor-Outdoor piping length 5m
w Reference value
OB272-1.qxp 02.1.26 1:22 PM Page 6