17
Check of indoor electronic control P.C. board
C
Check the both “parts side” and “pattern
side” of indoor electronic control P.C.
board visually.
Replace the fuse.
Is fuse(F11) blown?
Replace the fan
motor.
Replace the indoor
electronic control
P.C. board.
Is winding
resistance of
fan motor 0 "?
Is winding
resistance of
vane motor 0 "?
No
Ye s
Replace the vane
motor.
Ye s
Ye s
Is varistor(NR11) burnt?
Replace the varistor.
Ye s
Turn OFF the power supply.
Remove indoor fan motor connector CN211 and
vane motor connector CN151 from the indoor electronic
control P.C. board and turn ON the power supply.
No
Does the unit operate with the remote controller?
Does the OPERATION INDICATOR lamp light up
by pressing the EMERGENCY OPERATION switch?
Ye s
No
Turn OFF the
power supply.
Turn OFF the
power supply.
Varistor (NR11)
Indoor electronic
control P.C. board
Fuse (F11)
No
No
The unit does not operate with the remote controller. Also, the OPERATION INDICATOR lamp does not light up by
pressing the EMERGENCY OPERATION switch.
OB367D-1.qxp 12.1.13 7:49 AM Page 17
OB367D
Downloaded from AC-Manual.com Manuals

Other manuals for Mitsubishi MSH-GA60VB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MSH-GA60VB and is the answer not in the manual?

Mitsubishi MSH-GA60VB Specifications

General IconGeneral
BrandMitsubishi
ModelMSH-GA60VB
CategoryAir Conditioner
LanguageEnglish

Related product manuals