16
Yes
Yes
Check of indoor fan motor
A
Check of remote controller and receiver P.C. board
B
When OPERATION INDICATOR lamp flashes 3-time.
Indoor fan motor does not operate.
Repair or replace the indoor fan motor.
Disconnect lead wires from connector CN211 on the indoor electronic control P.C. board.
Measure resistance between lead wires No.3 and No.4 and then No.1 and No.4.
Are lead wires connected?
Reconnect the lead wires.
Is soldered point of the connector
correctly soldered?
Resolder it.
Is resistance 0 (short circuit) or (open circuit)?
Indoor unit operates by pressing the EMERGENCY OPERATION switch, but does not operate with the remote controller.
Replace the batteries (Refer to 9-1.4.).
Is noise heard from radio?
Are there any fluorescent lights of
inverter or rapid-start type within
the range of 1m?
Measure the voltage between receiver P.C. board connector CN301 No.1(+) and No.3(-) when the remote
controller button is pressed (Refer to 9-6.).
Is the voltage approximately 4 VDC?
Replace the indoor electronic control P.C.
board.
Replace the receiver P.C. board.
Replace the remote controller.
Reinstall the unit away from lights.
Attach a filter on receiving part.
Yes ( 0 or )
No
(others)
Yes
No
Yes
No
Is LCD display on the remote con-
troller visible?
Remove the batteries, then set them back
and press the RESET button. Check if the
unit operates with the remote controller.
Yes
Does the unit operate with the
remote controller?
Yes
OK
No
(not clear)
Yes
No
No
No (5V or 0 VDC)
No
Turn OFF the power supply.
Check connector CN211 visually.
w Check if the remote controller is exclusive for this air conditioner.
Turn ON the power supply. Stop it if the unit operate.
Insert screwdriver into air outlet to rotate indoor fan
motor slowly for 1 revolution or over, and measure
voltage between No.2(+) and No.3(-) on CN121.
Replace the indoor electronic control P.C. board.
Does voltage repeat 0 VDC and 5 VDC?
Yes
No
9-5. Troubleshooting flow
Turn ON a radio to AM and press
OPERATE/ STOP (ON/ OFF) button on
the remote controller.
Press OPERATE/ STOP (ON/ OFF)
button on the remote controller.
OB367D-1.qxp 12.1.13 7:49 AM Page 16
OB367D
Downloaded from AC-Manual.com Manuals

Other manuals for Mitsubishi MSH-GA60VB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MSH-GA60VB and is the answer not in the manual?

Mitsubishi MSH-GA60VB Specifications

General IconGeneral
BrandMitsubishi
ModelMSH-GA60VB
CategoryAir Conditioner
LanguageEnglish

Related product manuals