NAME
SYMBOL
NAME NAME
SYMBOL SYMBOL
AC,CT
CH
CNA
CND
CNS1
CNS2
CN1
CN2
CN3
CN4
CN5
CN6
CN40
CN41
CN51
CN3D
CNCT
C1,2
C3
C5
DS
D1
DCL
F.C
FUSE1
FUSE2
FUSE
IPM
LD1
MC
MF1,2
NF1
R1
R2
SLEV
SV1
SW1
SW2
SW3
SW4
SW5
SWU1
SWU2
SWU3
TB1
TB3
TB7
THHS
TH1
TH2
TH5
TH6
X1
X2
X3
ZNR
21S4
26C
52C
63HS
CURRENT DETECTION
CRANKCASE HEATER
CONNECTOR <POWER SUPPLY>
CONNECTOR <DC POWER SUPPLY>
CONNECTOR <MULTI SYSTEM>
CONNECTOR <CENTRALIZED CONTROL>
CONNECTOR <CONTROLLER DRIVE CONTROL>
CONNECTOR <POWER SYNC SIGNAL , PROTECTION>
CONNECTOR <POWER SUPPLY 30V , 12V , 5V>
CONNECTOR <INVERTER SIGNAL 5V>
CONNECTOR <IPM POWER SUPPLY>
CONNECTOR <IPM POWER SUPPLY , TROUBLE OUTPUT>
CONNECTOR <CENTRALIZED CONTROL POWER SUPPLY>
CONNECTOR <FOR STORING JUMPER CONNECTOR>
CONNECTOR <COMPRESSOR DRIVE SIGNAL OUTPUT>
CONNECTOR <DEMAND SIGNAL,SILENT MODE INPUT>
CONNECTOR <CURRENT DETECTION>
FAN MOTOR CAPACITOR
CAPACITOR<SMOOTHING>
CAPACITOR<POWER FACTOR IMPROVEMENT>
DIODE STACK
DIODE <POWER FACTOR IMPROVEMENT>
REACTOR
FAN CONTROL
FUSE(2A)
FUSE(6A)
FUSE(30A)
INTELLIGENT POWER MODULE
DIGITAL INDICATION LED
<OPERATION INSPECTION INDICATION>
COMPRESSOR
FAN MOTOR (INNER THERMOSTAT)
NOISE FILTER
RESISTOR<RUSH CURRENT PROTECT>
RESISTOR<DISCHARGE>
EXPANSION VALVE
SOLENOID COIL <HOT GAS BYPASS>
SWITCH <DISPLAY SELECTION SELFDIAGNOSIS>
SWITCH <FUNCTION SELECTION>
SWITCH <TEST RUN>
SWITCH <MODEL SELECTION>
SWITCH <FUNCTION SELECTION>
SWITCH <UNIT ADDRESS SELECTION,1ST DIGIT>
SWITCH <UNIT ADDRESS SELECTION,2ND DIGIT>
SWITCH <UNIT ADDRESS SELECTION,3RD DIGIT>
TERMINAL BLOCK <POWER SUPPLY>
TERMINAL BLOCK <TRANSMISSION>
TERMINAL BLOCK
<TRANSMISSION> (CENTRALIZED CONTROL)
THERMISTOR
<IPM RADIATOR PANEL TEMPERATURE DETECTION>
THERMISTOR<DISCHARGE TEMPERATURE DETECTION>
THERMISTOR
<LOW PRESSURE SATURATED TEMPERATURE DETECTION>
THERMISTOR
<PIPE TEMPERATURE DETECTION,JUDGING DEFROST>
THERMISTOR<OUTDOOR TEMPERATURE DETECTION>
RELAY
<CRANKCASE HEATER,MAGNETIC CONTACTOR>
RELAY<4-WAY VALVE>
RELAY<SOLENOID VALVE>
VARISTOR
4-WAY COIL
THERMAL SWITCH <COMPRESSOR>
MAGNETIC CONTACTOR
<INVERTER MAIN CIRCUIT>
HIGH PRESSURE SENSOR
<DISCHARGE PRESSURE DETECTION>
Always lit
87
-
1
2
4
3
6
5
8
7
(Example)
When the compressor and SV1 are
turned during heating operation.
6
-
-
5
SV1
4
21S4
3
2
52C
1
Indication
Bit
•During normal operation
The LED indicates the drive state of the controller in the outdoor unit.
1.Refer to the wiring boards of the indoor units for details on wiring of each indoor unit.
2.The transmission line is two-wire type and has no polarity.
3.Mark shows the terminal board,mark the connector .Symbols in parentheses () show the colors of connectors.
4.Self-diagnosis function
The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch(SW1) and LD1(LED indication)
found on the multi-controller of the outdoor unit.
LED indication : Set all contacts of SW1 to OFF.
Compressor operated