1.5 Outline of automatic operation
(1) Determination of operation mode
(a) SRK20, 25, 35, 50, 60ZJX, SRF and SRR series
The unit checks the indoor air temperature and the outdoor air temperature after operating the indoor and outdoor blowers
for 20 seconds, determines the operation mode and the indoor air temperature setting correction value, and then enters in
the automatic operation.
27.5
25.5
19.5
18
30
Outdoor air temperature (°C)
Indoor air temperature (°C)
Dehumidifying
Heating
Cooling
4) When the unit is operated automatically with the wired remote controller connected, the cooling operation is controlled accord-
ing to the display temperatures while the setting temperature is compensated by
+
C during dehumidifying or by
+
C during
heating.
SRF series
SRK, SRR series
Signals of wireless remote control (Display)
–6 –5 –4 –3 –2 –1
±
0 +1 +2 +3 +4 +5 +6
Setting Cooling
18 19 20 21 22 23 24 25 26 27 28 29 30
temperature Dehumidifying
18 19 20 21 22 23 24 25 26 27 28 29 30
Heating
20 21 22 23 24 25 26 27 28 29 30 31 32
Signals of wireless remote control (Display)
–6 –5 –4 –3 –2 –1
±
0 +1 +2 +3 +4 +5 +6
Setting Cooling
18 19 20 21 22 23 24 25 26 27 28 29 30
temperature Dehumidifying
19 20 21 22 23 24 25 26 27 28 28 30 31
Heating
20 21 22 23 24 25 26 27 28 29 30 31 32
Unit : °C
Unit : °C
27.5
25.5
18.0
18
30
(b)SRK25, 35ZJR-S, 20, 25, 35, 50ZJ-S, 71ZK-S series
Heating
Dehumidifying
Cooling
Indoor air temperature (˚C)
Outdoor air temperature (˚C)
A
1) The unit checks the temperature every hour after the start of operation and, if the result of check is not same as the previous
operation mode, changes the operation mode.
2) When the unit is started again within one hour after the stop of automatic operation or when the automatic operation is se
-
lected during heating, cooling or dehumidifying operation, the unit is operated in the previous operation mode.
3) Setting temperature can be adjusted within the following range. There is the relationship as shown below between the sig
-
nals of the wireless remote controller and the setting temperature.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SCM50ZJ-S1 and is the answer not in the manual?

Mitsubishi SCM50ZJ-S1 Specifications

General IconGeneral
BrandMitsubishi
ModelSCM50ZJ-S1
CategoryAir Conditioner
LanguageEnglish

Related product manuals